| Customization: | Available |
|---|---|
| Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
| Output Type: | Triple |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Title:FC-051P1K5T4E20H3BXCXXXSXXX VLT Drive 1.5kW 400V IP21 The FC-051P1K5T4E20H3BXCXXXSXXX is a VLT AutomationDrive FC-051 frequency converter rated at 1.5kW(2HP)for 3-phase 400V applications.This compact drive delivers 3.6A output current and features IP21 protection with built-in EMC filter and DC choke.Utilizing advanced VVC+technology,it provides precise motor control with automatic energy optimization.The unit supports multiple communication protocols including PROFIBUS DP and is designed for pumps,fans,conveyors,and other industrial applications requiring reliable variable speed control in challenging environments. Product Parameters Parameter Name Parameter Value Product Line VLT AutomationDrive FC-051 Model Number FC-051P1K5T4E20H3BXCXXXSXXX Rated Power 1.5 kW/2 HP Output Current 3.6 A Supply Voltage 3AC 380-480V±10% Output Frequency 0.2-400 Hz Control Principle VVC+(Voltage Vector Control) Protection Class IP21 Built-in Features EMC Filter,DC Choke,RFI Filter Communication PROFIBUS DP,Built-in RS-485 Ambient Temperature-10°C to+50°C Cooling Method Natural Convection Product Features This frequency converter employs VVC+technology for superior motor control without requiring encoder feedback.The integrated DC choke reduces harmonic distortion to below 40%and improves power factor.Built-in EMC and RFI filters ensure compliance with industrial emission standards while suppressing electromagnetic interference.The drive includes multiple application-specific macros for rapid commissioning in common applications. The thermal management system uses an optimized heat sink design for efficient cooling without forced ventilation.Comprehensive protection functions include motor thermal monitoring,short circuit protection,earth fault detection,and overvoltage/undervoltage protection.The intuitive control panel features a backlit LCD display for clear parameter visibility and easy operation. Advantages Integrated DC choke reduces harmonic distortion without external components,saving space and cost.Energy optimization feature can reduce power consumption by up to 10-15%in appropriate applications.IP21 protection enables reliable operation in environments with dripping water and falling particles. Compact design provides high power density while minimizing installation space.Flexible communication options support seamless integration into automation systems.Comprehensive diagnostic capabilities simplify troubleshooting and reduce maintenance time. Application Scenarios This drive is ideal for pump control in water supply and circulation systems.It serves fan applications in HVAC systems and industrial ventilation.The converter operates conveyor drives in material handling equipment and production lines. Other applications include mixer and agitator control in process industries.It is used in packaging machinery and automated production equipment.The drive serves irrigation systems and industrial washing applications requiring variable speed control. Usage Instructions Mount the drive vertically on a solid surface ensuring minimum clearance of 100mm above and below for air circulation.Connect power cables using appropriate fuses or circuit breakers as specified in the installation guide.Use shielded motor cables with proper grounding for EMC compliance. Select the appropriate application macro during initial setup based on your specific application.Enter motor parameters according to nameplate data precisely.Perform test runs at low speed without load before connecting to the driven equipment. Precautions Ensure adequate air circulation around the unit for proper heat dissipation.Do not exceed maximum cable lengths specified for motor connections(typically 25m shielded,50m unshielded).Always disconnect power before working on electrical connections. Use proper line protection devices as specified in the installation manual.Avoid installing in areas with excessive dust,moisture,or corrosive atmospheres despite IP21 protection.Verify motor compatibility with drive specifications before operation. Frequently Asked Questions What are the key benefits of the integrated DC choke in this drive? The integrated DC choke provides significant advantages by reducing line current harmonics to typically less than 40%total harmonic distortion(THD)without requiring external filters.This improves power quality throughout the electrical system and reduces stress on other equipment.The choke also limits inrush current during power-up,protecting the drive's DC bus capacitors and extending their service life.Additionally,it provides better immunity against line voltage disturbances and reduces the risk of nuisance tripping. The built-in design eliminates the need for external harmonic filters,saving panel space and reducing installation costs.For applications with strict power quality requirements or where multiple drives are installed,the integrated choke ensures compliance with harmonic standards without additional components.This feature is particularly valuable in facilities with sensitive electronic equipment that could be affected by power quality issues. How does the automatic energy optimization function work? The automatic energy optimization feature continuously monitors motor load and adjusts the magnetization level to minimize losses.During light load conditions,it reduces the motor flux,which decreases iron losses and improves overall efficiency.The system automatically adapts to load changes in real-time without affecting motor performance or requiring manual intervention. This function typically reduces energy consumption by 5-10%in variable torque applications like pumps and fans that frequently operate below full load.The optimization is particularly effective in applications with varying load profiles,as it maintains optimal efficiency across different operating conditions.The feature can be enabled or disabled through parameters,with recommended activation for most applications except those requiring maximum torque availability at all times. What maintenance procedures ensure long-term reliability? Regular maintenance should include quarterly visual inspections for dust accumulation,particularly on heat sinks and ventilation paths.Clean the unit using low-pressure compressed air if necessary,ensuring power is disconnected during cleaning.Semiannually,check all power and control connections for tightness,as thermal cycling can loosen terminals over time. Monitor the DC bus capacitors for any signs of bulging or leakage,though these components typically have a design life of 10+years under normal conditions.Annually,verify proper operation of all protection functions through testing.Keep a record of operating hours,fault history,and maintenance activities to identify trends and plan preventive maintenance effectively. |


Beijing Zhongping Technology Co., Ltd. is a leading provider of industrial automation solutions, intelligent robotics, and advanced system integration services. With decades of expertise, the company has established long-term strategic partnerships with global industry leaders such as Siemens, ABB, Schneider Electric, KUKA, Yaskawa, and FANUC, leveraging their cutting-edge technologies to deliver innovative, tailored solutions across diverse sectors.





Q1: What is the core business scope of Beijing Zhongping Technology Co., Ltd.?