Customization: | Available |
---|---|
Transport Package: | Carton |
Specification: | one |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The following content is generated by AI. Please consult customer service for detailed parameters. Title: AIRTAC GVR200-06 Precision Industrial Pressure Reducing Valve: A Comprehensive Guide Introduction: The AIRTAC GVR200-06 Precision Industrial Pressure Reducing Valve is a high-quality, reliable component designed for precise pressure control in various industrial applications. This valve is known for its robust construction, precise regulation, and ease of installation. It is widely used in industries such as oil and gas, chemical processing, and water treatment. Product Parameters Parameter Name Parameter Value Type Precision Industrial Pressure Reducing Valve Size 1/2" - 2" (DN15 - DN50) Connection Type Flanged, Threaded Pressure Range 0.1 - 10.0 MPa (1.5 - 150 bar) Flow Rate 0.1 - 100 m³/h Material Stainless Steel 316L Sealing Material PTFE, EPDM Operating Temperature -29°C to 200°C (-20°F to 392°F) Pressure Reducing Ratio 1:1 to 1:10 Product Features - Precision Regulation: The AIRTAC GVR200-06 valve offers precise pressure control, ensuring optimal performance and efficiency in industrial processes. - Robust Construction: Made of high-quality stainless steel 316L, this valve is resistant to corrosion and wear, providing long-lasting durability. - Easy Installation: The valve features a compact design and comes with various connection options, making it easy to install in different systems. - Wide Operating Range: The AIRTAC GVR200-06 valve can handle a wide range of pressures and temperatures, making it suitable for various industrial applications. Application Scenarios - Oil and Gas Industry: The valve is used for pressure control in pipelines, ensuring safe and efficient operation. - Chemical Processing: It is suitable for controlling pressure in chemical reactors, storage tanks, and other equipment. - Water Treatment: The AIRTAC GVR200-06 valve is used for pressure regulation in water treatment plants, ensuring optimal performance of the treatment process. Installation and Wiring - Installation Environment: The valve should be installed in a clean, dry, and well-ventilated area, away from direct sunlight and heat sources. - Connection Type: The valve can be connected using flanged or threaded connections, depending on the system requirements. - Pressure Testing: After installation, perform a pressure test to ensure that the valve is leak-proof and functioning correctly. Maintenance and Inspection - Regular Inspection: Inspect the valve regularly for any signs of damage, wear, or leakage. - Cleaning: Clean the valve regularly to remove any debris or sediment that may accumulate in the valve body. - Replacement: Replace worn-out or damaged parts, such as seals and gaskets, to maintain optimal performance. Precautions - Avoid over-tightening the connections, as this may damage the valve. - Do not use aggressive chemicals or solvents for cleaning the valve. - Ensure that the valve is compatible with the fluid being handled to avoid any chemical reactions or damage. FAQ 1. What is the pressure reducing ratio of the AIRTAC GVR200-06 valve? The AIRTAC GVR200-06 valve offers a pressure reducing ratio of 1:1 to 1:10, allowing precise control of the downstream pressure. 2. What materials are used in the construction of the AIRTAC GVR200-06 valve? The valve is made of high-quality stainless steel 316L, which is resistant to corrosion and wear. The sealing materials used are PTFE and EPDM, ensuring a reliable seal. 3. What is the operating temperature range of the AIRTAC GVR200-06 valve? The AIRTAC GVR200-06 valve can operate within a temperature range of -29°C to 200°C (-20°F to 392°F), making it suitable for various industrial applications. 4. How do I install the AIRTAC GVR200-06 valve? The valve can be installed using flanged or threaded connections. Ensure that the connections are tight and secure, and perform a pressure test after installation to check for leaks. 5. What are the maintenance requirements for the AIRTAC GVR200-06 valve? Regularly inspect the valve for any signs of damage or wear. Clean the valve regularly to remove debris or sediment, and replace worn-out parts as needed. 6. Can the AIRTAC GVR200-06 valve be used in high-temperature applications? Yes, the AIRTAC GVR200-06 valve can be used in high-temperature applications, as it has an operating temperature range of -29°C to 200°C (-20°F to 392°F). 7. What is the flow rate range of the AIRTAC GVR200-06 valve? The AIRTAC GVR200-06 valve can handle a flow rate range of 0.1 - 100 m³/h, making it suitable for various industrial applications. 8. What is the connection type available for the AIRTAC GVR200-06 valve? The valve is available with flanged and threaded connections, allowing for easy installation in different systems. 9. How do I perform a pressure test on the AIRTAC GVR200-06 valve? Perform a pressure test by connecting the valve to a pressure gauge and gradually increasing the pressure to the desired level. Check for any leaks or damage during the test. 10. What are the precautions to consider when using the AIRTAC GVR200-06 valve? Avoid over-tightening the connections, use compatible fluids, and ensure that the valve is installed in a suitable environment. Regular maintenance and inspection are essential to maintain optimal performance. |